當前位置:上海愛澤工業設備有限公司>技術文章>ABB 氧化鋯分析儀 AZ25 AZ20 產品簡介
技術文章

ABB 氧化鋯分析儀 AZ25 AZ20 產品簡介

閱讀:294發布時間:2017-10-20

The Endura AZ20 is the latest in a long line of high-quality, combustion gas analyzers from ABB.

The sensor, based on a zirconium oxide cell, is mounted at the tip of the probe that is inserted in the flue duct. The resulting direct, in situ measurement provides accurate and rapid oxygen reading for combustion ** / optimization and emissions monitoring purposes.

Endura AZ20 has been designed for extended periods of maintenance-free operation. The modular design with reduced component count improves the reliability and robustness of the system and simplifies breakdown repair if it occurs.

Kits containing all the parts needed to complete on-site repairs are available from ABB, ensuring that service personnel can effect repairs quickly and efficiently at minimum cost. The Endura AZ20probe has retained an easy-access cell arrangement, similar to the proven ZFG2 probe. This ensures cell replacement can be carried

out on-site using readily available, basic hand tools, even after long periods of high temperature operation.

The Endura AZ20 oxygen probe measures oxygen*** in flue gas using an in situ 'wet analysis' method. The 'wet analysis' method avoids measurement error (typically20% of reading higher than the actual value) that is ***by a sampling system using the 'dry analysis' method.

For customers with an existing installed ZFG2 probe with a ZMT or ZDT transmitter, a 55 V heater version of the Endura AZ20probe (the Endura AZ20 / ZFG2 replacement probe) is available.

System equipment comprises a (flue-mounted) Endura AZ20probe *** by an integral or remote transmitter. During operation, a zirconia cell within the probe is held at a constant temperature of 700°C (1292 °F) by a probe heater

thermocouple assembly. If the heater ***circuitry or software fails (unsafe), the probe heater power supply is switched off, ensuring the system fails 'safe' and protects the heater from an over-temp failure.

An output generated at the zirconia cell is processed in the transmitter giving a locally displayed O2 reading and a 4 to 20mA retransmission signal over any range between 0 % and 100% O2.

Optional automatic calibration (AutoCal*) enables automatic,semi-automatic or manual calibration to be performed using a probe-mounted gas*** manifold mounted within the probehead. Calibration sequencing is software-*** from thetransmitter.

Optional restrictors (where fitted*) in the probe head *** thetest gas and reference air flow without the need for flowmeters.The probe requires only preset test gas and reference airpressures of 1 bar (15 psi) to maintain a constant flow of 2.2 l /min (4.662 scfh). This flow is not affected by changes in themeasured gas pressure of ± 0.35 bar (5 psi). 

 

The Endura AZ25 combustion oxygen analyzer is the latest ina long line of high-quality, combustion gas analyzers fromABB. The AZ25 is designed to measure oxygen **** high temperature furnace atmospheres.

The sensor, based on a zirconium oxide cell, is mounted at thetip of the probe that is inserted directly into the furnace. Theresulting direct, in-situ measurement provides an accurate andrapid oxygen reading, for combustion optimizationand process quality ** purposes.

The in-situ technique provides a true oxygen measurementinside the process. It eliminates 'equilibrium shift' that iscommon to systems in which gas samples are extracted andcooled before measurement.

Reference air (500 to 1000 ml/min [1 to 2 ft3/hr]) is required foraccurate operation and can be supplied from an ABBmains-powered pump unit or a flow regulator unit.

Unique integrated automatic calibration

The Endura AZ25 automatic calibration system eliminates theneed for the expensive ancillary ***forautomatic calibration on ***l flue gas oxygen analyzersystems. ABB’s fully integrated, automatic calibration feature

** the test gas sequence and detects test gasavailability, eliminating incorrect calibrations due to loss of testgas. Integrated automatic calibration secures the oxygenmeasurement, providing complete confidence in the analyzer's

performance.

Long-term operation without technician ** minimizesoperating costs, total cost-of-ownership and optimizes systemaccuracy. A significant proportion of service visits to ananalyzer result in 'no fault found'. Endura AZ25's high-quality

manufacture, advanced diagnostics and automatic calibrationis targeted at reducing this wasted effort and cost.

Dependable

— measurement of O2 in a wide variety of processes

— virtually instantaneous response

— resistance to sulphurous reducing atmospheres

Versatile

— 600 to 1250 mm (2 to 4 ft) lengths

— choice of protective sheath materials

— integral thermocouple for automatic temperature

compensation

— high temperature operation up to 1400 °C (2552 °F)

Low cost-of-ownership

— in situ measurement

— no sampling system required

— automatic calibration functionality as standard

— optional automatic calibration hardware

Applications

— Furnace atmosphere monitoring:

— Annealing furnace

— Sintering of metals

— Ferrite sintering

— Whiteheart malleablizing

— Combustion measurement :

—Soaking pits

—Process heaters

—Fluidized bed boilers

—High temperature incinerators

— All other combustion processes where the flue gastemperature is in excess of 600 °C (1112 °F)

 

Aluminous porcelain

level sheath material suitable for applications withtemperatures up to 1250 °C (2282 °F) – limited resistant tocorrosive chemicals and mechanical and thermal stress.

Recrystallized alumina

Suitable for applications with temperatures up to 1400 °C(2552 °F) resistant to corrosive chemicals and more severemechanical and thermal stress are present.

Incoloy 800

Suitable for applications with temperatures up to 850 °C

(1562 °F) when mounted horizontally and up to 1000 °C

(1832 °F) when mounted vertically.

Offering limited resistance to corrosive chemicals and resistantmechanical and thermal stress.

愛澤工業(IZE_INDUSTRIES)銷售型號示例:

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0 /STD

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.1.1.1.1.0.0.0.0.E./STD

ABB 氧化鋯分析儀AZ25/.1.1.2.1.1.5.3.1.2.0.0.0.0.E.Z.J/STD

ABB 氧化鋯分析儀AZ20/112112225111100C/STD

ABB 氧化鋯分析儀AZ20/1.2.2.2.1.2.2.3.3.7.1.1.2.E

ABB 氧化鋯分析儀AZ20/222122337112E

ABB 氧化鋯分析儀AZ20/2.2.2.1.2.2.3.3.7.1.1.21.0.0.E/STD

ABB 氧化鋯分析儀AZ20/222122337112E/STD

如果您有任何關于產品的相關技術咨詢或者需要產品的相關技術資料與文檔,請隨時愛澤工業,或者訪問我們將盡全力解決您的問題。

If you have any question, please feel free to dial  or browse our Thank you.


泵閥商務網 設計制作,未經允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.fydnwx.com,All rights reserved.

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,泵閥商務網對此不承擔任何保證責任。 溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~
主站蜘蛛池模板: 宜城市| 苗栗市| 元氏县| 灵川县| 江北区| 衡山县| 海城市| 柯坪县| 子长县| 顺昌县| 英德市| 遵义县| 濮阳县| 迁西县| 广安市| 东兰县| 汝州市| 安庆市| 乌兰察布市| 岳西县| 景泰县| 灵川县| 竹溪县| 肇源县| 阿坝| 犍为县| 巴东县| 佳木斯市| 内丘县| 石阡县| 定襄县| 扎囊县| 普定县| 长子县| 五指山市| 和林格尔县| 阿鲁科尔沁旗| 定结县| 康保县| 常山县| 永仁县|